P.S.: Version v2.09 allows slower timebases 20, 50 and 100 ms/div with increased sample sizes up to 200 kS (-> 2 s sample time). sqrt( real*real + imag*imag )) instead of the real part only of the complex result of the discrete fourier transform. Martin P.S.: The nasty amplitude "pumping" of the spectrum trace is fixed with v2.08 - now I display the _magnitude_ of the spectrum (i.e. New feature: A check box for the included X10 probes, now the measurement and display doesn't have to be converted anymore - a simplification especially for hobby users and beginners.
Hantek 6022be software windows 10 free#
6022 has been using my free open source firmware already for quite some time. The good result is that OpenHantek6022 is now completely free open source - all nonfree Hantek firmware is now removed.
Hantek 6022be software windows 10 code#
Also, these devices behave very differently in USB communication and require a variety of switch cases and #defines and inflate the code unnecessarily. Ciao, MartinĪnother big step: OpenHantek6022 now only supports 6022BE and 6022BL, all older devices (2090, 2150, 22) have been removed (because I don't own any of these devices and can't test them). I've collected some more HW documentation in my github repo in directory "hardware". Therefore I don't need to stick on factor 1/10. I'm using OpenHantek that allows me to read in an individual calibration file with offset and gain for each channel and each gain step. As I use the device with linux only I'm able to change the program. My approach is similar to yours, but I only reduce R31/21 from 100k to 90k to be able to safely measure my 5V TTL levels without clipping and use a 1:10 divider for higher voltages (I am planning to build a 1:100 divider for 230V mains measurements). With our device the common mode voltage is 0 V Have a look at Common-Mode Voltage: Due to R8 inside the AD9288 the output of the U11 is also pulled up a liitle bit so that my real input range in is -5.2V.+4.8V. Correct is +- 512 mV between Ain and /Ain where the common mode voltage should be 0.7.1.1 V. The problem with the 6022BE is that the ADC AD9288 operates far outside its spec. Wouldn't it be better to use a 1:10 probe to measure >5V? My device only measures up to +4.8 V before the signal is limited. Your approach is ok as long as you don't want to measure small voltages, because you lose resolution. Hi Charles, I'm also about to modify the input stage of my 6022B. activated channel, probe x1/x10) when leaving/closing. Changing the V/div-adjustment only works when both channels are set to the same value - When changing the time of data aquiring ("recording") the timebase-adjustment is set to a low value (w/o a need) - The software looses all adjustments (e.g. The vertikal position of the channels is not adjustable - sometimes it is good drawing them on the same baseline (zero), but sometimes the "traditional" appearance with left channel in the upper and right channel in the lower part od the screen is better. But there are some bug, maybe depending on using BL´s HTMarch.dll (I own a 6022BL, so I can not check this with a 6022BE): - The top preview-Window only shows "events", waves, of channel 1. posts here I exspected that it also supports the 6022BL but it did not so). It runs also with 6022bl after replacing the HTMarch.dll by the HTMarch.dll from BL´s SDK-package (after reading the reg. Yesterday I checked the last version of PCScope I found. Anyway, I got the PR19 version from the link It is a shame the developer stopped working on Open6022BE and nobody could took over the project, it is really promising and by far the best alternative to the official software. I don't have a 6022BL at hands now, but I quickly tested the Open6022BE PR19 with a 6022BE and couldn't reproduce the hanging problem, there is a lot of other bugs, but no hanging. I am using Win 10 but I tested it in a Win7 VM.
Hantek 6022be software windows 10 install#
When you see only the yellow exclamation mark, download the latest drivers from Hantek and manually install the Win 10 driver (even if you are using Windows 7), apparently this is the newest driver and what worked better for me.
Unplug an plug the device again to confirm that there is no driver left in the system. Try to do this: Open the Windows Device Manager and mark the option "Show hidden devices" in "View" menu.